跳转到主内容

使用 SP API 服务的命令失败,并且证书颁发机构( CA )签名的证书配置不正确

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core<a>FSE</a>
Last Updated:

适用场景

ONTAP 9

问题描述

cluster1::> system node power show
               
Node        Status    
---------------- -----------
Error: The Service Processor on node "cluster1-01" is not reachable. Check the network configuration, verify that the node is running, verify that the SP is online, verify that api-service is enabled on the SP, and try the command again.

cluster1::> system node power show
Error: unknown state (SSL_error_code = 1) exception occurred in spcc_system_power_status code

cluster1::*> system node coredump trigger -node cluster1-01
Error: command failed: Secure connection failed with the Service Processor on node "cluster1-01". Contact support.

cluster1::> system node environment sensors show
Warning: Unable to list entries on node cluster1-01. SSL_connect: unknown state (SSL_error_code = 1) exception occurred in spcc_sp_get_sensor_info code cluster1-01

Error: SSL_connect: unknown state (SSL_error_code = 1) exception occurred in DsmdbServer code

cluster1::> system node environment sensors show 
Node Sensor          State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi    
---- --------------------- ------ ----------- -------- -------- ------- -------
node-1a
   PSU2 FRU        normal     GOOD
   PSU1 FRU        normal     GOOD
   SP Status        normal IPMI_HB_OK
   mSATA Status      normal      OK
   mSATA Pres       normal   PRESENT
 
Warning: Unable to list entries on node node-1a. The Service
     Processor on node "node-1a" is not reachable. Verify that
     the SP or BMC is online, verify that api-service is enabled on the SP
     or BMC, verify that the partner node is running, check if pings from
     SP or BMC to partner node work, check if hw-assist keep-alives are
     normal, check that network ports are configured correctly and are
     functional (up). Then, try the command again.
 
node-1b
   PSU2 FRU        normal    GOOD
 
Warning: Unable to list entries on node node-1b. Timeout: Operation
     "environment_sensors_iterator::next_imp()" took longer than 50
     seconds to complete [from mgwd on node "node-1a" (VSID: -1)
     to mgwd at 192.168.205.7]
 
Error: show failed: Timeout: Operation
    "environment_sensors_iterator::next_imp()" took longer than 50 seconds
    to complete [from mgwd on node "node-1a" (VSID: -1) to mgwd at
    <Node-1a_intracluster_IP>]

  • helves and Sensors check 验证ONTAP 升级期间出现S错误消息:

::> cluster image show-update-progress
                         Estimated      Elapsed
Update Phase      Status           Duration     Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks   failed           00:10:00     00:04:21
 
Details:
 
Pre-update Check    Status       Error-Action
-------------------- ----------------- --------------------------------------     
Shelves and Sensors  Error        Error: Validation check failed to
check                  execute properly.
                    Action: If the problem persists after
                    retrying, delete the package and
                    download again

cluster1::*> system service-processor api-service check -node cluster1-01

Date: Mon Mar 27 16:10:06 2023
Node: sselab-01
Port: 50000
  Local Private IPv4: failed(192.0.2.80)  
   Local Public IPv4: failed (10.10.10.10) 
   Local Public IPv6: (Unable to get IP address)

      Target Node: cluster1-02
         IPv4: failed (10.10.10.11)
         IPv6: (Unable to get IP address)

  • Ping操作适用于服务处理器IP地址。
  • 安全证书已过期。示例: 

::> security certificate show -fields vserver,common-name,serial,ca,type,expiration -type server     
vserver common-name serial       ca     type   subtype cert-name expiration
------- ----------- ---------------- -------- ------ ------- --------- ------------------------
...
svm    svm_name   12AB3CDE45F6G789 svm_ca  server -     svm_cert Fri Jun 30 14:35:51 2022

     

    Sign in to view the entire content of this KB article.

    New to NetApp?

    Learn more about our award-winning Support

    NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.