问题描述

多路径(MPIO)软件允许主机维护LUN的多个路径。指向LUN所在NetApp节点的路径被视为"主动/优化"路径、而通过该节点的HA配对节点的路径被视为"主动/未优化"路径。具体术语可能因主机操作系统和多路径驱动程序而异。在某些情况下、可能会导致一个或多个路径无法访问或无法用于I/O根据不可用的路径、主机可能会出现性能下降、尤其是在没有其他"活动/优化"路径的情况下。 

路径状态由当前拥有LUN的节点使用 ALOA确定。发生接管时、接管其配对节点LUN所有权的节点路径将变为"主动/优化"状态。

RedHat "multipath -ly"输出中的路径故障示例: 

# multipath -ll
mpath0 (360a9800043346441464a44424c746e54)
[size=10 GB][features="1 queue_if_no_path"][hwhandler="0"]
_ round-robin 0 [prio=8][active]
_ 0:0:0:0 sda 8:0   [failed][faulty]
_ 1:0:0:0 sdi 8:128 [active][ready]
_ round-robin 0 [prio=2][enabled]
_ 0:0:1:0 sde 8:64  [active][ready]
_ 1:0:1:0 sdm 8:192 [active][ready]

RedHat "/var/log/messages "示例:

Jun 22 15:55:54 rhel1 multipathd: Lun1: sdcr - tur checker reports path is down
Jun 22 15:55:54 rhel1 multipathd: checker failed path 69:240 in map Lun1
Jun 22 15:55:54 rhel1 multipathd: Lun1: remaining active paths: 3
Jun 22 15:55:54 rhel1 kernel: device-mapper: multipath: Failing path 69:240.


VMware vmkernel示例:

2017-11-30T07:17:41.351Z cpu15:33143)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe: NMP device "sym.029025256531353837" state in doubt; requested fast path state update...
2017-11-30T07:17:41.351Z cpu15:33143)WARNING: ScsiPath: 4507: Path vmhba2:C0:T0:L55 is being removed
2017-11-30T07:17:41.351Z cpu15:33143)WARNING: ScsiPath: 6117: Remove path: vmhba2:C0:T0:L55


Windows的"系统事件日志"示例:

Information   10/31/2017 4:39:33 PM   mpio     46    None   Path 1000001 was removed from \Device\MPIODisk2 due to a PnP event. The dump data contains the current number of paths.
Information   10/31/2017 4:39:33 PM   ontapdsm   61070   None   Path ID 01000001 was removed.
Warning     10/31/2017 4:39:33 PM   ontapdsm   61054   None   Path ID 01000001 has failed and 02000101 will be used instead.
Error      10/31/2017 4:39:33 PM   ontapdsm   61142   None   Path ID 01000001 has failed.


注:确切的日志条目可能会因操作系统版本以及多路径的配置方式而异。 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.