FCP/FCoE LIF报告因交换机SFP出现故障而运行中断
适用场景
- ONTAP 9
- FCP或FCoE
- Cisco 交换机
问题描述
- 启动程序无法连接到FCP LIF或访问该LIF提供的LUN。
Network interface show
输出会将FCP LIF的状态报告为已由管理员启动且操作已关闭。
cluster1::> network interface show -data-protocol fcp
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
fcp-svm
fcp-lif up/down 20:03:00:a0:xx:xx:xx:xx cluster1-01 0f true
Network fcp adapter show
输出将适配器状态报告为“Link disconnected"
。
Cluster1::> network fcp adapter show –fields status
node adapter status
------------- ------- ------
Cluster1-01 0f link disconnected
SYSCONFIG-A
输出将状态显示为""Link disconnected
。
slot 0: Fibre Channel Target Host Adapter 0f
(QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
Firmware rev: 8.9.0
Flash rev: 5.0.2
Host Port Addr: 000000
FC Nodename: 50:0a:09:80:xx:xx:xx:xx(500a0980xxxxxxxx)
FC Portname: 50:0a:09:81:xx:xx:xx:xx(500a0981xxxxxxxx)
Connection: No link
Switch Port: Unknown
SFP Vendor Name: AVAGO
SFP Vendor P/N: AFBR-57F5MZ-NA1
SFP Vendor Rev: 01
SFP Serial No.: xxxxxxxxx
SFP Connector: LC
SFP Capabilities: 4, 8, 16 Gbit/Sec
show interface transceiver
已连接Cisco交换机上的输出报告受影响存储连接端口的Tx功率低。