由于 Vscan 防病毒扫描软件的背压,在 CIFS 共享上经历了巨大的延迟

Views:
86
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

适用于

  • ONTAP 9
  • VSCAN 

问题

  • 客户端在数据访问中遇到间歇性延迟
  • VSCAN 间歇性断开与 SVM 的连接并且未扫描文件
  • EMS 日志显示以下错误消息

 [?]  Fri Dec 08 04:13:44  0000 [Node1: kernel: ems.engine.suppressed:debug]: Event 'Nblade.vscanConnBackPressure' suppressed 439 times in last 84151 seconds.
 [?]  Fri Dec 08 04:13:44  0000 [Node1: kernel: Nblade.vscanConnBackPressure:error]: For Vserver "svm", AV server "10.48.xx.xx" is too busy to accept new scan requests.
 [?]  Fri Dec 08 04:16:18  0000 [Node1: kernel: Nblade.vscanConnInactive:notice]: For Vserver "svm", ONTAP(R) forcibly closed the vscan connection originated from the nonresponsive AV server "10.48.xx.xx".
 [?]  Fri Dec 08 04:16:18  0000 [Node1: OffboxVScanTableUpd: Nblade.scannerDisconnected:notice]: Vserver "svm" disconnected from Vscan server (IP: 10.48.xx.xx).

  • 将 VSCAN 服务器上排队请求的阈值数从 1 增加到 24,但问题仍然存在

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.