跳转到主内容

由于Vscan超时、对大型zip文件进行SMB重命名可能会失败并出现内部错误

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas<a>2009316749</a>
Last Updated:

适用场景

  • ONTAP 9
  • Vscan (实时)
  • Windows
  • CIFS/SMB

问题描述

  • 启用实时Vscan后、客户端会失败SMB重命名操作、并显示内部错误
  • 可能会发现受影响SVM和共享的延迟增加
  • 已禁用强制扫描
  • 根据SMB2_COM_SET_INFOEMS/ event log show 条目、在CIFS操作超时时时、SMB重命名操作()失败:
Nblade.CifsOperationTimedOut: Detected a timed out CIFS operation.
SMB command for this operation: SMB2_COM_SET_INFO,
Number of times this command was suspended: 6,
Number of times this command was restarted: 0,
Last CSM error during this operation: CSM_OK,
Remote blade UUID: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx (cluster01n01),
Is QoS enabled: QoS_disabled,
Last SpinNp error during this operation: SPINNP_ERR_OFFBOX_VSCAN_REQD, Client IP address: xxx.xxx.xxx.xxx, Local IP address: xxx.xxx.xxx.xxx,
Target Vserver ID: 12, Target disk's DSID: 1234
 
  • 显示数据包跟踪 STATUS_INTERNAL_ERROR

SetInfo Response, Error: STATUS_INTERNAL_ERROR

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
Scan to view the article on your device
  • 这篇文章对您有帮助吗?