在诊断模式下、EMS显示消息"secd.unexpectedFailure:Vserver (集群)意外故障"
适用场景
- ONTAP 9
- LDAP
问题描述
- LDAP已配置为管理SVM的源。
::> vserver services name-service ns-switch show -vserver cdot
Source
Vserver Database Order
--------------- ------------ ---------
cdot hosts files,dns
cdot group files,ldap
cdot passwd files,ldap
3 entries were displayed.
- 在以
"diag"
模式登录到集群命令行界面后、EMS日志会显示在Debug"消息下方
::> set diag
Warning: These diagnostic commands are for use by NetApp personnel only.
Do you want to continue? {y|n}: y
cdot::*> event log show -event secd.unexpectedFailure*
Time Node Severity Event
------------------- ---------------- ------------- ---------------------------
7/7/2022 16:56:55 cdot-01 DEBUG secd.unexpectedFailure: vserver (Cluster) Unexpected failure. Error: Ldap Get full user info procedure failed
**[ 0] FAILURE: 'Ldap' configuration not available
7/7/2022 16:56:00 cdot-01 DEBUG secd.unexpectedFailure: vserver () Unexpected failure. Error: Ldap get list of groups for a user procedure failed
**[ 0] FAILURE: 'Ldap' configuration not available
注意: 在ONTAP 9.11.1及更高版本中、严重性已更新为error
-
"admin"
以模式登录时、不会显示相同的调试消息
::*> set admin
::> event log show -event secd.unexpectedFailure*
There are no entries matching your query.