集群交换机运行状况监控器在 9.8 及更高版本中报告 "SNMP 设置无效 "
适用场景
- 集群网络交换机
- ONTAP 9.8
问题描述
- 在ONTAP 9.8及更高版本中、尝试使用命令"system cluster-switch cree"或"system switch Ethernet cree"创建集群交换机条目失败、并显示以下错误消息:
::> set advanced
::*> system switch ethernet create -device switch1 -address 10.10.10.1 -model OTHER -type cluster-network -is-monitoring-enabled-admin true
Error: SNMP validation request timed out. Verify that the "-community-or-username" value is valid.
- "system cluster-switch show"命令输出的"reason"字段的值为"Invalid SNMP Settings"
::> system cluster-switch show -type cluster-networkSwitch Type Address Model--------------------------- ------------------ ---------------- ---------------switch1 cluster-network 10.10.10.1 N9K-C9336C-FX2Serial Number: XXXXXXXXIs Monitored: falseReason: Invalid SNMP SettingsSoftware Version: Cisco Nexus Operating System (NX-OS) Software, Version9.3(8)Version Source: CDP/ISDP- ONTAP与交换机之间没有网络连接问题