跳转到主内容

This Site will be down for up to 3 hours on December 2, 2023 from 8 PM - 11 PM PST, to deploy an infrastructure update.

临时 vifmgr.port.monitor.failed 错误。未通过 "l2_reachable" 运行状况检查

Views:
29
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • FAS2720/AFF-A220
  • ONTAP 9.7P7
  • 集群网络交换机( CNS ) Cisco Nexus N3K-C3132Q-V
  • MetroCluser-IP ( MCC-IP )

问题描述

  • 在不同节点和端口中随机显示几条临时 L2 可访问性 EMS 消息。示例:

Thu Dec 03 15:57:33 +0100 [node_name: ctran_clam_0: ems.engine.suppressed:debug]: Event 'csm.connCookieNotFound' suppressed 19 times in last 702 seconds.
Thu Dec 03 15:57:33 +0100 [node_name: ctran_clam_0: csm.connCookieNotFound:debug]: Session (req=cc51A:dblade, rsp=node_name:dblade, uniquifier=0b05b2e186d65fb2): connection cookie 1011 is invalid.
Thu Dec 03 15:57:38 +0100 [node_name: vifmgr: vifmgr.bcastDomainPartition:error]: Broadcast domain Cluster is partitioned into 2 groups on node node_name. The different groups are: {e0a}, {e0b}. LIFs hosted on the ports in this broadcast domain may be at the risk of seeing connectivity issues.
Thu Dec 03 15:57:44 +0100 [node_name: vifmgr: vifmgr.port.monitor.failed:error]: The "l2_reachability" health check for port e0a (node node_name) has failed. The port is operating in a degraded state.
Thu Dec 03 15:57:44 +0100 [node_name: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: Insufficient L2 Reachability - Insufficient L2 Reachability detected from cluster port e0a on node node_name.
Thu Dec 03 15:57:44 +0100 [node_name: vifmgr: vifmgr.portDeg.lifMoved:notice]: LIF node_name-clus1 (on virtual server 4294967293), IP address 169.254.114.29, is being moved to node node_name, port e0b from node node_name, port e0a because the port's health status is in a degraded state.
Thu Dec 03 15:57:46 +0100 [node_name: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF node_name-clus1 (on virtual server 4294967293), IP address 169.254.114.29, is now hosted on node node_name, port e0b.
Thu Dec 03 15:57:46 +0100 [node_name: vifmgr: vifmgr.port.monitor.passed:notice]: The "l2_reachability" health check for port e0a (node node_name) has passed.
Thu Dec 03 15:57:46 +0100 [node_name: vifmgr: vifmgr.portHealthy:notice]: The health status of port e0a (node node_name) has changed from degraded to healthy. This port can now be used for hosting LIFs.

  • 报告问题的集群端口连接到不同的 MCC-IP 集群网络交换机( CNS )。
  • MCC-IP 集群网络交换机正在运行兼容的固件和 RCF 文件。
  • 交换机日志 "# show tech-support" 中未报告任何问题。
  • 端口和 VLAN 的 ifstat 输出中未报告任何问题。

 

 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.