由于LIF故障转移策略分配不正确、无法执行节点接管
适用场景
- ONTAP 9
- FAS / AFF
- SAN LIF
问题描述
- 节点接管失败并显示错误:
cluster1::> storage failover takeover -ofnode Node1
(storage failover takeover)
Warning: A takeover will be initiated. When the partner node reboots, a giveback
will be automatically initiated. Do you want to continue?
{y|n}: y
Error: command failed: Could not migrate LIFs away from node "Node1":
Reason Failed to migrate one or more LIFs away from node
"Node1". Use the "network interface show -curr-node
Node1" command to identify LIFs that could not be migrated off
that node. Use the "network interface migrate" command to manually
migrate the LIFs off the node. Run "storage failover show" to confirm
node "Node1" is operational. If node is operational, reissue
the takeover command with "-skip-lif-migration-before-takeover" to skip
the migration and proceed with takeover.
- 正在使用的LIF基于SAN。