适用场景

  • ONTAP 9
  • 自动化无中断升级(ANDU)
  • 批处理方法

问题描述

  • 在ANDU ONTAP升级期间、数据LIF (逻辑接口)迁移失败、导致升级过程暂停。
  • 当节点接管其配对节点时、配对节点的生命周期将根据网络接口故障转移目标规则进行迁移。
  • 在此场景中、由于配对 节点不属于数据LIF故障转移目标、因此它尝试故障转移到集群中的另一个节点。
    • 由于目标节点在升级过程中不可用、LIF迁移失败。

示例:

::> net int show -vserver test -lif lif4 -fields failover-group
  (network interface show)
vserver  lif  failover-group
-------- ---- --------------
test    lif4  TEST 

::> network interface failover-groups show -failover-group TEST
                  Failover
Vserver      Group       Targets
---------------- ---------------- --------------------------------------------
<admin vserver>
         TEST
                  node-04:a0a-105, node-01:a0a-105

::> cluster image show-update-progress
                                           Estimated         Elapsed   
-------------------- ----------------- --------------- ---------------  
Pre-update checks    completed                00:10:00        00:02:09
Data ONTAP updates   paused-on-error          02:34:00        02:59:26  

Details:   

Node name            Status            Status Description   
-------------------- ----------------- --------------------------------------    
node-01            waiting
node-02            completed
node-03            waiting                                                          
node-04            failed            Error: Failed to migrate data LIFs             
                                       from node "node-04".                            
                                       Action: Migrate all of the data LIFs          
                                       migrate -vserver <vserver-name> -lif
                                      <data-lif-name> -dest-node node-03" command.
node-05           waiting
node-06           completed
node-07           waiting    
          
Status: Paused-An error occurred in "Data ONTAP updates" phase.The update cannot continue until the error has been resolved.

事件日志\EMS:

Thu Apr 01 16:01:03 -0700 [node-02: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the 
cluster has been paused due to the following reason:
Node "node-03": Error: {Failed to migrate data LIFs from node "node-04".}, 
Action: {Migrate each of the data LIFs using the "network interface migrate
 -vserver  -lif  -dest-node node-03" command.}.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.