已针对调解器磁盘报告 adapterHardwareErrorEMSOnly
适用场景
- MetroCluster IP
- Cisco ACI
- 调解器
问题描述
已针对调解器磁盘报告 adapterHardwareErrorEMSOnly 错误
scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000abe0:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [123] UID [123]
scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [123] UID [123]
scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [123] UID [123]