跳转到主内容

遇到致命错误后, T6 卡端口关闭

Views:
11
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2008702702</a>
Last Updated:

适用场景

  • 双 40/100G 以太网 T62100-CR 卡
  • MetroCluster IP
  • AFF-A700/FAS9000
  • AFF-A400
  • AFF-A800

问题描述

  • 在遇到致命错误后,两个 40/100G 以太网 T62100-CR 卡的端口关闭:
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.linkDown:info]: Ethernet e1a: Link down, check cable.
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.fatal.err:alert]: The network device in slot 1 encountered fatal error e1a/e1b.
 
  • 可能会发生节点重新启动、并在控制台上显示以下错误: 
e5a/e5b (t6nex0): ! PL_PERR_CAUSE 0x19404 = 0x00000001, E 0x1fffe3ff, F 0xffffffff e5a/e5b (t6nex0): ! [0x00000001] CIM e5a/e5b (t6nex0): * PL_INT_CAUSE 0x1940c = 0x00100041, E 0x1fffe77d, F 0x00000000 e5a/e5b (t6nex0): * [0x00100000] MA e5a/e5b (t6nex0): * [0x00000040] PL e5a/e5b (t6nex0): * [0x00000001] CIM e5a/e5b (t6nex0): ! MA_INT_CAUSE 0x77e0 = 0x00000002, E 0x00000007, F 0x00000006 e5a/e5b (t6nex0): ! MA_PARITY_ERROR_STATUS1 0x77f4 = 0x00020000, E 0x00000000, F 0xffffffff e5a/e5b (t6nex0): ! PL_PL_INT_CAUSE 0x19430 = 0x00000018, E 0x00000010, F 0x00000010 e5a/e5b (t6nex0): ! [0x00000010] Fatal parity error e5a/e5b (t6nex0): ? [0x00000008] e5a/e5b (t6nex0): firmware reports adapter error: Crash (0xc014c010)
  • 节点重新启动后,端口可能会完全恢复,也可能会在短时间内恢复,然后再重新关闭

 

 

 

 

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.