跳转到主内容

已报告 DegradedOnlineShelfPort_Alert

Views:
5
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009061507</a>
Last Updated:

适用场景

  • AFF-A220
  • FAS2720
  • FAS8200
  •  ONTAP 9
  • MetroCluster IP

问题描述

已报告 DegradedOnlineShelfPort_Alert
 
::*> system health alert show
        Node: Node-01
      Alert ID: DegradedOnlineShelfPort_Alert
      Resource: Shelf 1.1
      Severity: Major
   Indication Time: Wed May 31 14:10:49 2023
      Suppress: false
     Acknowledge: false
   Probable Cause: Shelf-to-shelf connection between disk shelves 1.1 3 port and 1.3 1 port have 2 inactive PHYs on IOM A.
   Possible Effect: Inactive PHYs might cause degraded link performance.
 Corrective Actions: 1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
           2. Verify that disk shelf 1.1 has disabled PHYs by using the "storage shelf show -shelf 1.1 -port" command.
           3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.1 3 port cable on IOM A and disk shelf 1.3 1 port cable on IOM A.
           4. Verify that the physical cable connection is secure and operational, and replace the cable, if necessary.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.