已报告 DegradedOnlineShelfPort_Alert
- Views:
- 5
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009061507</a>
- Last Updated:
适用场景
- AFF-A220
- FAS2720
- FAS8200
- ONTAP 9
- MetroCluster IP
问题描述
已报告 DegradedOnlineShelfPort_Alert
::*> system health alert show
Node: Node-01
Alert ID: DegradedOnlineShelfPort_Alert
Resource: Shelf 1.1
Severity: Major
Indication Time: Wed May 31 14:10:49 2023
Suppress: false
Acknowledge: false
Probable Cause: Shelf-to-shelf connection between disk shelves 1.1 3 port and 1.3 1 port have 2 inactive PHYs on IOM A.
Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Verify that disk shelf 1.1 has disabled PHYs by using the "storage shelf show -shelf 1.1 -port" command.
3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.1 3 port cable on IOM A and disk shelf 1.3 1 port cable on IOM A.
4. Verify that the physical cable connection is secure and operational, and replace the cable, if necessary.