跳转到主内容

在机头交换操作步骤 期间, DR 配对 NVLog 镜像未联机

Views:
28
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • 光纤 MetroCluster
  • ONTAP 9
  • 从 AFF-A300 到 AFF-A400 的标题交换
  • 从AF-A700/FAS9000到AF-A900/FAS9500的人员更换

问题描述

  • 完成 MetroCluster 中第一个站点的机头交换后,完成第一个切回后,切换模拟将失败

示例:

ClusterA::*> metrocluster operation show
    Operation: switchover-simulate
      State: failed
    Start Time: 2/19/2022 22:19:52
     End Time: 2/19/2022 22:19:57
      Errors: Failed to validate the node and cluster components before the switchover operation.
          ClusterB::ClusterB-01 (non-overridable veto): DR partner NVLog mirroring is not online.
          ClusterB::ClusterB-02 (non-overridable veto): DR partner NVLog mirroring is not online.

  • 尽管 FCVI 设备状态为 " 已启动 " ,但 DR 镜像也报告为脱机

ClusterA::> metrocluster interconnect mirror show
              Mirror   Mirror
          Partner Admin   Oper
Node Partner Name Type   Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
ClusterA-01
   ClusterA-02
          HA    enabled  online
                      mlx4_0  IB    Up
                      mlx4_0  IB    Up
   ClusterB-02
          DR    enabled  offline
                      fcvi_device_0
                          FC-VI  Up
                      fcvi_device_1
                          FC-VI  Up
   ClusterB-01
          AUX    enabled  offline
                      fcvi_device_0
                          FC-VI  Up
                      fcvi_device_1
                          FC-VI  Up

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.