跳转到主内容

DR 配置复制失败— AutoSupport 消息

Views:
34
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster
  • SVM-DR
  • DR 配置复制失败

事件摘要

此消息表示Storage Virtual Machine (SVM)遇到和问题描述 、无法将其配置复制到MetroCluster 或SVM-DR配置中的第二个集群。

这些错误可能会阻止成功的 MetroCluster 切换 / 切换操作或存储虚拟机 DR 操作。

DRCGFM:HA Group Notification from <node name> (DR CONFIG REPLICATION FAILED) ERROR

验证

运行以下命令以确定无法复制的SVM:

MetroCluster :

::> metrocluster vserver show
Cluster: ClusterA
                            Partner                       Configuration
Vserver                     Vserver                       State
-------------------         ----------------------        -----------------
ClusterA                    ClusterB                    healthy
SVM1                        SVM1-mc                       healthy
vserver_nas                 vserver_nas-mc                healthy

Cluster: ClusterB
                            Partner                       Configuration
Vserver                     Vserver                       State
-------------------         ----------------------        -----------------
ClusterB                   ClusterA                      healthy
vserver_san                 vserver_san-mc                healthy

 

SVM-DR:

::> event log show -event *Configuration Replication*

解决方法

如果系统拥有有效的支持合同且系统正在向NetApp发送AutoSupport 消息、则会自动创建DR配置复制失败案例。

要确定问题描述 的原因、请查看以下指南:

功能 解决方案
MetroCluster
如何确定MetroCluster 中的DR配置复制失败问题
DR配置复制失败问题(MetroCluster)
SVM-DR
DR配置复制失败问题(SVM DR)

追加信息

附加信息 _text

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.