跳转到主内容

通过 100G MuxPonder 的长距离 ISL 不会形成中继

Views:
2
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
san
Last Updated:

适用场景

  • 100 克 MuxPonder
  • Brocade 交换机
  • FCP
  • WDM

问题描述

  • 通过 100G MuxPonder 的远程 ISL 不会在 Brocade 交换机中形成中继
admin> islshow
  1:  0-> 0 10:00:d8:1f:xx:xx:xx:xx   8 remote_switch  sp:  8.000G bw:  8.000G TRUNK CR_RECOV
  2:  1-> 1 10:00:d8:1f:xx:xx:xx:xx   8 remote_switch  sp:  8.000G bw:  8.000G TRUNK CR_RECOV

admin> trunkshow
1: 0-> 0 10:00:d8:1f:xx:xx:xx:xx 8 deskew 0 E-Port MASTER
2: 1-> 1 10:00:d8:1f:xx:xx:xx:xx 8 deskew 0 E-Port MASTER

admin> trunkdebug 0, 1
port 0 and 1 can't trunk due to one of the following reasons:
ports are not same speed or valid speed
ports are not same long distance mode
local or remote ports are not in same port group
difference between links length is greater than allowed

  • 在正确形成的中继线上、输出类似于以下内容:

admin> trunkshow
1: 0-> 0 10:00:d8:1f:xx:xx:xx:xx 8 deskew 0 E-Port MASTER
   1-> 1 10:00:d8:1f:xx:xx:xx:xx 8 deskew 0 E-Port

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.