跳转到主内容

由于电源故障,Brocade 交换机状态从 HEALTHY 更改为 CRITICAL

Views:
118
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用于

  • Brocade G620 交换机
  • Brocade G720 交换机

问题

  • 切换状态已从 HEALTHY 更改为 CRITICAL ,根据  errdump
  • psshow

psshow -v     :
Power Supply #1 is faulty
Power Supply #2 is OK

  • sensorshow:

sensorshow     :
sensor  1: (Temperature) is Ok, value is 33 C
sensor  2: (Temperature) is Ok, value is 41 C
sensor  3: (Temperature) is Ok, value is 37 C
sensor  4: (Temperature) is Ok, value is 36 C
sensor  5: (Temperature) is Ok, value is 37 C
sensor  6: (Temperature) is Ok, value is 32 C
sensor  7: (Temperature) is Ok, value is 56 C
sensor  8: (Fan     ) is Ok,speed is 8141 RPM
sensor  9: (Fan     ) is Ok,speed is 8043 RPM
sensor 10: (Power Supply) is Faulty
sensor 11: (Power Supply) is Ok

  • errdump

CHASSIS, ERROR, BrocadeG620, PS 1 set to faulty, rc=2000e.
WARNING, NSWNT-DC-B, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.
WARNING, NSWNT-DC-B, Switch wide status has changed from HEALTHY to CRITICAL.

  •  多个故障警报(PSU 和风扇)在  errdump

CHASSIS, ERROR, BrocadeG720, PS 2 set to faulty, rc=2000e.
CHASSIS, ERROR, BrocadeG720, Fan 2 set to faulty, rc=2000e.

CHASSIS, WARNING, BrocadeG720, 1 blower failed or missing. Replace failed or missing blower assembly immediately.
WARNING, BrocadeG720, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.
WARNING, BrocadeG720, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
WARNING, BrocadeG720, Switch wide status has changed from HEALTHY to CRITICAL.
WARNING, BrocadeG720, Fan speed of all the fan FRUs changing to 17400 RPM as per environmental specifications.
CHASSIS, INFO, BrocadeG720, Fan 2 is Ok.
CHASSIS, INFO, BrocadeG720, PS 2 is Ok.
WARNING, BrocadeG720, Switch wide status has changed from CRITICAL to HEALTHY.
WARNING, BrocadeG720, Fan speed of all the fan FRUs changing to 12200 RPM as per environmental specification

  • 检查 PSU 的电源是否松动

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.