跳转到主内容

由于交换机端 SFP 故障,Brocade 交换机端口出现抖动并脱机

Views:
78
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用于

  • 所有 Brocade 交换机硬件平台
  • 所有 Brocade Fabric Operating System (FOS) 固件级别

问题描述

  • 端口状态为 In_sync

 254  12   30   68fe40   id   N32    In_Sync    FC

  • 端口显示为离线

portshow 254
portDisableReason: None
portCFlags: 0x1
portFlags: 0x4041    PRESENT U_PORT LED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2   Offline  

  • 结构日志显示端口已多次抖动

15:16:55.961101 SCN Port Offline;rsn=0x4,g=0x3b7e       A2,P0  A2,P0  254  NA   
15:16:55.961107 *Removing all nodes from port         A2,P0  A2,P0  254   NA   
15:17:40.649127 SCN LR_PORT(0);g=0x3b7e            A2,P0  A2,P0  254   NA   
15:17:40.695392 SCN Port Online; g=0x3b7e,isolated=0     A2,P0  A2,P1  254   NA   
15:17:40.695851 Port Elp engaged               A2,P1  A2,P0  254   NA   
15:17:40.695865 *Removing all nodes from port         A2,P0  A2,P0  254   NA   
15:17:40.696094 SCN Port F_PORT                A2,P1  A2,P0  254   NA   
16:02:58.997554 SCN Port Offline;rsn=0x4,g=0x3b80       A2,P0  A2,P0  254   NA   
16:02:58.997560 *Removing all nodes from port         A2,P0  A2,P0  254   NA   
16:02:59.008547 SCN LR_PORT(0);g=0x3b80            A2,P0  A2,P0  254   NA 

  • sfpshow 显示端口具有较低的 Tx 值

Slot 12/Port 30:
=============
Identifier:  3   SFP
Connector:   7   LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
Encoding:   6   64B66B 
Vendor Name: BROCADE      
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01  
BR Min:    0   
Serial No:   JAF418510000PG1 
Date Code:   181219  
Temperature: 50    Centigrade 
Current:    6.542   mAmps 
Voltage:    3325.5  mVolts 
RX Power:   -2.9   dBm (518.3uW) 
TX Power:   -40.0   dBm (0.1   uW)

  • Errdump 可能显示以下内容: 

    2025/06/23-22:58:05 (IST), [MAPS-1003], 881081, SLOT 2 | FID 128 | PORT 5/22, WARNING, NTTC_X6_UAT_105_FAB1, slot5 port22-Storage..PMAX_1144_c1P12.(SHARED_BAU.IBM PowerVIOs-, U-Port 5/22, Condition=ALL_PORTS(LOSS_SIGNAL/min>3), Current Value:[LOSS_SIGNAL, 7 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Category=Port Health, Quiet Time=None."
  • Porterr 显示报告链接失败错误


/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
 254:    5.0k    5.0k    0       0       0       0       0       0     156       0       2.0k  234       3       0       0       0       0       0       0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.