SolidFire节点上出现"绑定1G/绑 定10G上的已设置网络配置不匹配"警报
适用场景
- NetApp SolidFire
- NetApp HCI存储节点
问题描述
- 从Active IQ检测到以下
networkConfig
警告。
示例:
Detected network configuration mismatch on Bond1G:
{ - "#default" : false,
+ "#default" : true,
"address" : "xx.xx.xx.xx",
"auto" : true,
"bond-downdelay" : "0",
@@ -9,10 +9,18 @@
"bond-primary_reselect" : "Failure",
"bond-slaves" : "eth2 eth3",
"bond-updelay" : "200",
+ "dns-nameservers" : "xx.xx.xx.xx",
"family" : "inet",
+ "gateway" : "xx.xx.xx.xx",
"method" : "static",
"mtu" : "1500",
"netmask" : "xx.xx.xx.xx",
"network" : "xx.xx.xx.xx",
- "status" : "UpAndRunning"
+ "status" : "UpAndRunning",
+ "symmetricRouteRules" : [ + "ip route add xx.xx.xx.xx/23 dev Bond1G src xx.xx.xx.xx table Bond1G",
+ "ip route add default via xx.xx.xx.xx",
+ "ip route add default via xx.xx.xx.xx dev Bond1G src xx.xx.xx.xx table Bond1G",
+ "ip rule add from xx.xx.xx.xx table Bond1G" + ] }
Detected network configuration mismatch on Bond10G: