跳转到主内容

"sensorReadingFailed" 和 "ensembleDegraded" 警报被检测到

Views:
22
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用于

  • NetApp SolidFire
  • NetApp Element 软件 12.3.2 版本之前

问题描述

  • NetApp SolidFire Active IQ 和 Element 集群 Web GUI 上可以看到以下警报:
    • sensorReadingFailed IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.
    • ensembleDegraded Ensemble degraded: 1/5 database servers not connectable: {3:x.x.x.x}
  • 存储节点的远程控制台显示 EXT4-fs 错误
    • [3367598.061077] EXT4-fs error (device sda2): ext4_journal_check_start:61:Detected aborted journal
    • [3367598.061078] EXT4-fs error (sda2): Remounting filesystem read-only xxxxxxxx
    • [3367598.125694] EXT4-fs error (sda3): in ext4_writepages:2878: IO failure
  • 事件日志显示:

networkEvent Failed to install SSL certificate  3  { "message": "Failed to remove path=[/sf/etc/ssl/active.crt] errorCode=system:30 errorCode.message()=Read-only file system", "name": "xCheckFailure" }
platformHardwareEvent Updating BMC cold reset date 6 3  { "bmcResetDurationMinutes": 0, "bmcResetDate": "2021-05-11T23:16:41" }
unexpectedException Unexpected Exception - xCreateRepositorySourceFileFailed Failed to open and truncate /sf/apt/sources.list.new.tmp callback=[ {4:RepositorySources::packageManagerCallbackTag}] wtype=[SessionConnected] - Contact SolidFire Support. 6 3  ""

  • 生成支持捆绑包时发生以下错误:

Error creating support bundle: SolidFireApiError server=[xx.xx.xx.xx]
method=[CreateSupportBundle], params=[{'bundleName': 'supportbundle', 'extraArgs': ' --binary'}] - error name=[xAPIMethodFailed],
message=[Create Support Bundle failed processing:
 command=timeout -s KILL 1500s /sf/scripts/sfsupportbundle --quiet ?--binary
/tmp/solidfire-dtemp.ScjN9i/supportbundle
 cmdResult={ rc=1 stdout="" stderr="mount: /: cannot remount /dev/sda2 read-write, is write-protected.
mv: cannot move '/var/log/sf-supportbundle.info.3' to '/var/log/sf-supportbundle.info.4': Read-only file system

  • 启用SSH API已成功实现,但操作系统无法启动SSH服务
  • 节点的BMC网页可以正常访问,1G/10G网络可以访问

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.