跳转到主内容

'bnx2x_Attn_int_desertedX - SolidFire 节点上发生 CFC 致命错误

Views:
10
Visibility:
Public
Votes:
1
Category:
element-software
Specialty:
solidfire
Last Updated:

适用于

  • NetApp SolidFire 存储节点
  • NetApp Element 软件( 11.7 及更低版本)
  • NIC 驱动程序 bnx2x 版本 1.712.30-0

问题

运行kern.log*sys.log完整的内核文件()和(): 

  • [bnx2x_attn_int_deasserted(X):4219(eth<X>)]CFC hw attention 0x2
  • [bnx2x: [bnx2x_attn_int_deasserted(X):(XXXX)(eth<X>)]FATAL error from CFC
     

通常,这会在 NetApp SolidFire Active IQ 中导致以下错误:

  • fileSystemCapacityLow - File System /var/log has <X>% free space (below 5%). Please contact support.

如果问题未及时解决,则会出现其他(可能的)错误

  • nodeOffline - The SolidFire Application cannot communicate with node ID <X>.
  • unresponsiveService - A master service is not responding.
  • memoryUsageThreshold - System memory is very low. Adding additional nodes or manually purging deleted volumes may help reduce memory usage.
  • authenticationServiceFault - Unable to determine status of Element Auth container on node 2. Please contact support if this problem persists.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.