跳转到主内容

更换驱动器后、StorageGRID设备报告驱动器隔离导致存储控制器E2800上发生冗余MEL不匹配事件

Views:
2
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software<a>2009586126.</a>
Specialty:
esg
Last Updated:

适用场景

  • StorageGRID设备SG6060
  • StoageGRID设备的E系列控制器E2800

问题描述

Auto Support为驱动器隔离打开了案例、从而导致冗余不匹配。
 
E系列阵列中的主要事件日志显示即将发生的驱动器先前已触发到保留容量的驱动器副本。

B:5/22/23, 7:48:36 PM (19:48:36) 5208 3803 Disk pool reconstruction reserved drive count is below threshold - Disk Pool StorageGRID-disk-pool99 <--CRITICAL
B:5/22/23, 7:48:36 PM (19:48:36) 5207 227e Drive copy started - Shelf 99, Drawer 4, Bay 5
A:5/22/23, 7:48:36 PM (19:48:36) 5206 3803 Disk pool reconstruction reserved drive count is below threshold - Disk Pool StorageGRID-disk-pool99 <--CRITICAL
B:5/22/23, 7:48:34 PM (19:48:34) 5205 1023 Drive copy triggered by a controller detected impending drive failure - Shelf 99, Drawer 4, Bay 5 - WWN: 5000ccaxxxxxx

后来、驱动器出现故障并更换了POST、错误数据复制回新磁盘、E系列将驱动器隔离、以避免冗余不匹配。

A:5/25/23, 12:05:35 AM (00:05:35) 5287 2046 Isolation of drive causing redundancy mismatch - Shelf 99, Drawer 4, Bay 5 - LBA: 0x1f440dc00 - SSID: 0x12 = 18 <--CRITICAL
A:5/25/23, 12:05:35 AM (00:05:35) 5286 2035 Redundancy not consistent - Volume StorageGRID-obj-14 - SSID: 0x12 = 18 - LBA: 0x00000000, Blocks:32768
A:5/24/23, 2:02:24 PM (14:02:24) 5282 380a Disk pool reconfiguration started - Disk Pool StorageGRID-disk-pool99
A:5/24/23, 2:02:17 PM (14:02:17) 5281 2401 Hot swap monitor detected drive insertion - Shelf 99, Drawer 4, Bay 5 - WWN: 5000cca0c8245314
A:5/24/23, 2:01:50 PM (14:01:50) 5280 2858 Drawer closed - Shelf 99, Drawer 4
B:5/24/23, 2:02:27 PM (14:02:27) 5279 380a Disk pool reconfiguration started - Disk Pool StorageGRID-disk-pool99
B:5/24/23, 2:02:20 PM (14:02:20) 5278 2263 The drive replacement succeeded - Shelf 99, Drawer 4, Bay 5
B:5/24/23, 2:02:20 PM (14:02:20) 5277 2228 Drive deleted - Shelf 99, Drawer 4, Bay 5
B:5/24/23, 2:02:14 PM (14:02:14) 5276 2401 Hot swap monitor detected drive insertion - Shelf 99, Drawer 4, Bay 5 - WWN: 5000ccaxxxxxx
B:5/24/23, 2:01:47 PM (14:01:47) 5275 2858 Drawer closed - Shelf 99, Drawer 4
B:5/24/23, 2:01:39 PM (14:01:39) 5274 101f Summary of impending drive failure detected by controller - Shelf 99, Drawer 4, Bay 5 - Detected by: 0, Sense Key: 0
----> Current/Cumulative Recovered Errors: 0/10, Medium Errors: 0/0, Hardware Errors: 0/0, Stagnant IO: 0/0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.