适用场景

  • NetApp EF 系列
  • NetApp SANtricity OS 11.70.3及更早版本

问题描述

EF系列控制器会随机重新启动、并且可能会发生发生原因 卷故障。

  1. 下载 支持包
  2. 打开 stateCaptureData 文件
  3. 验证是否显示以下错误:

示例:

Log Entry #44 (Core 0) Sep-16-2022 09:25:06 AM ----


PCI SERR Exception
SERR Summary: 0x00000020
SERR Return Status: 0x00000000
SERR Collection Count: 0x2
   PCI-E Root to PLX9797-1  (Unit 1)
   VID 0x8086 DID 0x2030 B100:D0:F0
   Bridge Secondary PCI Status = 0x2000
   PCI-E XP Uncorrectable Status = 0x00000040
   SERR Summary Flags = 0x80000021
   PLX9797-1 Port 0 to Drive11  (Unit 15)
   VID 0x10b5 DID 0x9797 B102:D11:F0
   PCI-E Device Status = 0x000D
   PCI-E AER Uncorrectable Status = 0x00100000
     Header Log 0 = 0x05008001
     Header Log 1 = 0x64000003
     Header Log 2 = 0x71000000
     Header Log 3 = 0xf5b8304c
   PCI-E AER Correctable Status = 0x00008000
   PCIe Link down.
   SERR Summary Flags = 0x80000063
NOTE: Recovered from NVME Link-Down Errors

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.