跳转到主内容

在启动期间,控制器在 7 段显示器上显示 0F 更换

Views:
35
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
esg
Last Updated:

适用于

控制器: E27XX

固件版本: 08.20.05.00

问题

在更换控制器期间,新控制器不会启动,并且在 7 段显示器上显示 0F 。

正在执行双控制器更换。存储系统中更换的第一个控制器工作正常,没有任何问题。更换第二个控制器后,它将锁定,并在 7 段显示器中显示 0F 。在初始启动过程中,不会显示任何错误。excLogShowSTATE_CAPTURE支持包中文件的输出显示以下错误:

Unexpected PCI bus width x0 for BDF[1,9,0] TRIGGERING LOCKDOWN.

Unexpected PCI bus speed x1 for BDF[1,9,0] TRIGGERING LOCKDOWN.

 

PCI DEVICE 0 NOT FOUND: Host-side Fibre Device=0 Function=0 ClassCode=0xc0400

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: Host-side Fibre Device=0 Function=0 ClassCode=0xc0400

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

PCI DEVICE 0 NOT FOUND: Host-side Fibre Device=0 Function=1 ClassCode=0xc0400

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: Host-side Fibre Device=0 Function=1 ClassCode=0xc0400

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

PCI DEVICE 2 NOT FOUND: iSCSI Ethernet Device=0 Function=2 ClassCode=0x20000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: iSCSI Ethernet Device=0 Function=2 ClassCode=0x20000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

PCI DEVICE 2 NOT FOUND: iSCSI Ethernet Device=0 Function=3 ClassCode=0x20000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: iSCSI Ethernet Device=0 Function=3 ClassCode=0x20000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

PCI DEVICE 0 NOT FOUND: Host-side iSCSI Device=0 Function=4 ClassCode=0x28000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: Host-side iSCSI Device=0 Function=4 ClassCode=0x28000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

PCI DEVICE 0 NOT FOUND: Host-side iSCSI Device=0 Function=5 ClassCode=0x28000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0 TRIGGERING LOCKDOWN.

 

PCI DEVICE NOT ACCESSIBLE: Host-side iSCSI Device=0 Function=5 ClassCode=0x28000

ParentBridge=PLX PCI-E Bridge to Host Card Port 0

 

安装更换的 HIC 或使用两个额外的备用控制器无法解决此问题。

 

请致电 NetApp 技术支持并提及此文章以获得帮助。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.