SolidFire PionThread 核心转储自动生成
适用于
- NetApp Element OS v12.8
- NetApp H-Series 存储节点
问题描述
- 在从 Element OS v12.7 升级到 v12.8 期间,检测到针对集群存储节点的核心转储,并显示以下警报:
Alert: SFOTHW: SolidFireAlert from <Cluster-Name>(OtherP3) CorenodeID=3, path=/sf/core.PionThread-1.53413.gz, modifiedTime=2025-10-29T15:20:42Z
- 核心分析的相关日志输出:
#2 0x00007f81b604e47b in abort() from /sf_debug/12.8.0.1156/lib64/libc.so.6
#3 0x00007f81b74b9eaf in OpenSSLDie() from /sf_debug/12.8.0.1156/usr/lib64/libcrypto.so.1.0.0
#4 0x00007f81b75d93e0 in ssl_load_ciphers() from /sf_debug/12.8.0.1156/usr/lib64/libssl.so.1.0.0
#5 0x00007f81b75e0d55 in SSL_library_init() from /sf_debug/12.8.0.1156/usr/lib64/libssl.so.1.0.0
#6 0x00007f81b66afc3e in tls_o_init() from /sf_debug/12.8.0.1156/usr/lib64/libldap-2.4.so.2
#7 0x00007f81b66ac0bd in ldap_int_tls_init_ctx() from /sf_debug/12.8.0.1156/usr/lib64/libldap-2.4.so.2
#8 0x00007f81b66a0eec in ldap_set_option() from /sf_debug/12.8.0.1156/usr/lib64/libldap-2.4.so.2
- 业务影响:无。未观察到服务中断或节点离线事件。集群和节点健康状况始终保持"健康"。