节点关闭后未安装 NVRAM 卡,切片服务未响应
适用于
- NetApp Element 软件 11.8 及更高版本
- NetApp H610S
- NetApp H410S
问题描述
节点关闭后,节点重新启动时 NVRAM 卡无法安装。
- ActiveIQ/WebGUI 警报:
NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. error={NVRAM device partition exists, but not mounted}- 日志 (
sf-master.info) :
2024-06-13T13:51:44.792486Z node01 master-1[66879]: [EXPERR-4] [Nvram] 68965 GlobalPool-0 serviceshared/NvramDeviceNvdimm.cpp:523:GetStatusWithSuppression|Suppressing Nvdimm status result=[{ status=Error statusInfo={(Error,{NVRAM device partition doesn't exist})}}]2025-06-14T09:37:21.029332Z node01 sfmount: Mounting dev="/dev/pmem0" mnt="/mnt/pendingDirtyBlocks"
2025-06-14T09:37:21.304975Z node01 sfmount: Failed to mount dev="/dev/pmem0" mnt="/mnt/pendingDirtyBlocks" stdout="" stderr="mount: /mnt/pendingDirtyBlocks: wrong fs type, bad option, bad superblock on /dev/pmem0, missing codepage or helper program, or other error."注意: 如果多个节点受到意外断电的影响,
volumeOffline也可能会检测到这种情况。