跳转到主内容

多磁盘错误导致HA节点关闭

Views:
4
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>2009872778</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • DS460C

问题描述

  • 多磁盘崩溃会导致节点重新启动。EMS中会显示以下错误消息:
12/7/2023 17:03:00  node-03 ERROR        cf.multidisk.fatalProblem: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr1_n3: raid volfsm, fatal multi-disk error..
Raid type - raid_dp
Group name plex0/rg0 state NORMAL. 5 disks failed in the group.
Disk 0c.40.6 Shelf 40 Drawer 1 Slot 6 Bay 6 [NETAPP   X375_WVELE04TA07 NA01] S/N [V1K65EJG] UID [5000CCA0:BCB45494:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist.
Disk 0c.40.7 Shelf 40 Drawer 1 Slot 7 Bay 7 [NETAPP   X375_WVELE04TA07 NA01] S/N [V1K6AZMG] UID [5000CCA0:BCB4A7F0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk.
Disk 0c.40.8 Shelf 40 Drawer 1 Slot 8 Bay 8 [NETAPP   X375_WVELE04TA07 NA01] S/N [V1K6B4PG] UID [5000CCA0:BCB4AA64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist.
Disk /aggr1_n3/plex0/rg0/0c.40.9 Shelf 40 Drawer 1 Slot 9 Bay 9 [NETAPP   X375_WVELE04TA07 NA01] S/N [V1K4J.
Because more than two disks are faulty, the aggregate status is failed
  • 聚合状态显示为故障。

Aggregate aggr2_n3 (failed, raid_dp, partial, fast zeroed) (block checksums)
Plex /aggr2_n3/plex0 (offline, failed, inactive)
RAID group /aggr2_n3/plex0/rg0 (partial, block checksums)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.30.27 0a 30 27 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
parity 0b.41.34 0b 41 34 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.34 0d 31 34 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0a.30.28 0a 30 28 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.35 0b 41 35 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.35 0d 31 35 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0a.30.29 0a 30 29 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.42 0b 41 42 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.42 0d 31 42 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0a.30.36 0a 30 36 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.43 0b 41 43 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.43 0d 31 43 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0c.40.42 0c 40 42 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.37 0a 30 37 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
Raid group is missing 3 disks.
Aggregate aggr1_n4 (failed, raid_dp, partial) (block checksums)
Plex /aggr1_n4/plex0 (offline, failed, inactive)
RAID group /aggr1_n4/plex0/rg0 (partial, block checksums)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity FAILED N/A 3807816/ -
parity 0d.31.25 0d 31 25 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.25 0b 41 25 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.33 0a 30 33 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0d.31.26 0d 31 26 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.26 0b 41 26 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.34 0a 30 34 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0d.31.27 0d 31 27 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.27 0b 41 27 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.35 0a 30 35 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0c.40.36 0c 40 36 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.28 0d 31 28 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.28 0b 41 28 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.42 0a 30 42 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0c.40.37 0c 40 37 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
Raid group is missing 3 disks.
Aggregate aggr2_n4 (failed, raid_dp, partial) (block checksums)
Plex /aggr2_n4/plex0 (offline, failed, inactive)
RAID group /aggr2_n4/plex0/rg0 (normal, block checksums)
RAID group /aggr2_n4/plex0/rg2 (partial, block checksums)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0b.41.14 0b 41 14 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
parity 0a.30.22 0a 30 22 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0c.40.17 0c 40 17 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0d.31.15 0d 31 15 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.15 0b 41 15 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.23 0a 30 23 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0d.31.16 0d 31 16 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.16 0b 41 16 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.30 0a 30 30 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0d.31.17 0d 31 17 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.17 0b 41 17 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0a.30.31 0a 30 31 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data FAILED N/A 3807816/ -
data 0d.31.24 0d 31 24 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0b.41.24 0b 41 24 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168
data 0c.40.53 0c 40 53 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
Raid group is missing 3 disks.

  • 这些磁盘均位于同一抽盒中。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.