如果Vserver托管VVOV应用程序、则Vserver迁移将失败
适用场景
- ONTAP 9
- SVM迁移
- SVM数据移动性
- Appdm (应用程序感知型数据管理)
问题描述
- 如果尝试迁移托管VVOV应用程序感知型数据管理(Appdm)的Vserver、则迁移将失败:
DstCluster::> vserver migrate show
Destination Source
Vserver Cluster Cluster Status
---------------- ------------------- ------------------- ---------------------
SrcVserver DstCluster SrcCluster Migrate-failed
Status Details: Migrate operation failed. Reason: Application of configuration failed for Vserver "SrcVserver". Reason: Failed
when polling for the migrate operation completion for Vserver "SrcVserver". Reason: Apply failed for Object: appdmObjectUI Method: baseline. Reason: Application "ISO" was not found in Vserver "SrcVserver". To resume the Vserver migrate operation, use the "vserver
migrate resume" command. To change the source Vserver configuration, use the "vserver migrate pause" command on the destination cluster, make the
configuration changes on the source cluster, and then use the "vserver migrate resume" command on the destination cluster.