由于大型集群中的网络LIP数量、EMS会报告splog.sp.not.accessible
适用场景
- ONTAP
- AFF A900、AFF A800、AFF A700、AFF A320、AFF A300、 AFF A220、AFF A200、AFF A150、AFF C190
- FAS9500、FAS9000、FAS8200、FAS2750、FAS2720、 FAS2650、FAS2720
问题描述
- EMS 报告 ""。
splog.sp.not.accessible
2/1/2023 13:58:38 node1 ERROR splog.sp.not.accessible: The SP on the remote node (node2) is not accessible because of The Service Processor on node "node2" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again..
system node power show
命令将显示以下错误消息:
Error: The Service Processor on node "node2" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner
node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.
- 发生Telnet超时:
[root@xxxx~]# telnet xx.xx.xxx.xxx:50000
Trying xx.xx.xxx.xxx...
telnet connect to address xx.xx.xxx.xxx: Connection timed out
- 可以正常访问SP或BMC