跳转到主内容

CONAP-384790:卷移动后FlexGroup上出现高延迟或访问问题

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

问题描述

  • 卷移动后的成分卷不会出现高延迟、而是应在同一节点上的其他成分卷上出现高延迟  
  • 高延迟会在卷移动完成后立即开始。
  • 在同一节点上的其他成分卷上可能会出现访问问题  
  • 仅将FlexGroup作为FlexClone父级是不够的。所需条件如下:
    • FlexGroup FlexClone父级
    • 父节点在该节点上的成分卷大于或等于2个
    • 克隆成分卷也位于该节点上、并且尚未拆分。如果克隆成分卷/配置文件已拆分或移动到另一个节点、则不会出现此问题。如果存在多个克隆、则此操作会适用场景所有克隆。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.