跳转到主内容

卷移动未进行、重复数据删除未准备好进行卷移动转换

Views:
18
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core<a>2008957826</a><a>进行翻译</a>
Last Updated:

适用场景

  • ONTAP 9
  • 存储 效率

问题描述

  • Volume move 停留在复制阶段、无法进行  

::*> vol move show -instance
Vserver Name: svm1
Volume Name: volume1
Volume Instance UUID: f5c831f1-87df-4494-9b3c-2508f8e5b658
Actual Completion Time: -
Bytes Remaining: 264.2GB
Bytes Sent: 28.04TB
Status Code: -
Completion String: -
Specified Action For Cutover: retry_on_failure
...
Percentage Complete: 98%
Move Phase: replicating
Prior Issues Encountered: 10/25/2021 13:04:24 : Preparing source volume for cutover: Deduplication is not ready for volmove cutover
10/25/2021 13:03:16 : The estimated time to complete cutover is greater than the cutover window that can be tolerated by the user
10/25/2021 11:49:51 : Volume is not quiesced
10/25/2021 11:46:49 : The estimated time to complete cutover is greater than the cutover window that can be tolerated by the user
10/25/2021 11:45:41 : Volume is not quiesced

 
  • 在中 /mroot/etc/log/sis.log
Thu Oct 21 10:00:00 MDT 2021 [Vserver UUID: 09d34037-342a-11e7-a5b3-00a0985e9ae7] /vol/volume1 [sid: 0] Error (A volume move operation is in progress. Use the "volume move show" command to view the status of the move. Retry this command when the move is complete. )
  • 未运行卷效率功能、但已启用实时效率功能:

::*> volume efficiency show -vserver svm1 -volume volume1
                    Vserver Name: svm1
                    Volume Name: volume1
                    Volume Path: /vol/volume1
                       State: Enabled
                     Auto State: -
                      Status: Idle
                     Progress: Idle for 118:04:53
                       ...
                   Inline Dedupe: true
                  Data Compaction: true
         Cross Volume Inline Deduplication: true
                Application IO Size: 8K
               Compression Algorithm: lzopro
       Cross Volume Background Deduplication: true
              Extended Compressed Data: true
    Volume has auto adaptive compression savings: false
       Volume doing auto adaptive compression: false

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.