跳转到主内容

为什么不能为iSCSI SAN LUN启用自动故障转移?

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • SAN
  • ISCSI
  • ONTAP OS 9.11.1之前的版本

问题解答

  • 在  9.11.1之前的SAN环境中,FC/iSCSI LUN不会进行故障转移。
  • 然后、  如果  在接管/恢复期间或节点脱机期间、指向托管LUN的节点的目标路径关闭、则由主机使用MPIO (多路径)软件管理流量故障转移到其他可用路径。
  • 只要我们安装了适用于主机操作系统的MPIO软件、并且主机可以访问这两个节点、我们就不会遇到任何 与到/GB相关的问题。

追加信息

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.