跳转到主内容

更新ESXi和HBA驱动程序后、VM崩溃

Views:
8
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san<a>2009年354959</a>
Last Updated:

适用场景

  • ONTAP 9.3P19
  • VMware ESXi 7.0U3
  • HPE Synergy CNA 6820c

问题描述

  • ESXi从6.7升级到7.0U3、其中涉及到将HBA (HPE Synergy CNA 6820c)固件升级到8.55.31以及将驱动程序升级到2.2.70
  • VM崩溃
  • 由于存储延迟较长、虚拟机性能下降
  • 数据存储库可能会断开连接
  • vmkernel.log 指示读取(10)、重试:

ScsiDeviceIO: 4124: Cmd(0x45d9c8bba388) 0x28, CmdSN 0x17706 from world 2593788 to dev "naa.600a09803830377a4124496f41704874" failed H:0xc D:0x0 P:0x0

  • EMS 日志

fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:9c IO WQE failure, Handle 0xa, Type 8, S_ID: 1091C, VPI: 3, OX_ID: 282, Status 0x3 Ext_Status 0x1d
fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:9c IO WQE failure, Handle 0xa, Type 8, S_ID: 1091C, VPI: 3, OX_ID: 25F, Status 0xc Ext_Status 0x0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.