E系列中断后、无法恢复所有FlexArray磁盘
适用场景
- ONTAP
- FlexArray
问题描述
disk show
从后端中断中恢复后、AutoSupport 中的命令和FDR (故障磁盘注册表)会将某些磁盘显示为故障Sysconfig
命令 不会显示任何故障磁盘。
::> disk show c07e1.13
Disk: c07e1.13
Container Type: broken
Owner/Home: netapp-01 / netapp-01
DR Home: -
Stack ID/Shelf/Bay: - / - / -
LUN: 101
Array: netapp
Vendor: NETAPP
Model: INF-01-00
Serial Number: 60080E5000437690000001D957xxxxxx
UID: 60080E50:00437690:000001D9:57xxxxxx:00000000:00000000:00000000:00000000:00000000:00000000
BPS: 512
Physical Size: 568.8GB
Position: present
Checksum Compatibility: block
Aggregate: -
Plex: -
Paths:
LUN Initiator Side Target Side Link
Controller Initiator ID Switch Port Switch Port Acc Use Target Port TPGN Speed I/O KB/s IOPS
------------------ --------- ----- -------------------- -------------------- --- --- ----------------------- ------ ------- ------------ ------------
netapp-01 0g 101 netapp-sw1:3 netapp-sw1:12 AO INU 20320080e5xxxxxx 0 16 Gb/S 0 0
netapp-01 6b 101 netapp-sw2:2 netapp-sw2:11 ANO RDY 20230080e5xxxxxx 1 16 Gb/S 0 0
netapp-02 0g 101 netapp-sw1:8 netapp-sw1:13 AO INU 20420080e5xxxxxx 0 16 Gb/S 0 0
netapp-02 6b 101 netapp-sw2:7 netapp-sw2:10 ANO RDY 20130080e5xxxxxx 1 16 Gb/S 0 0
Errors:
This disk is in a failed state with the outage reason "failed". The Disk needs to be removed and replaced.
- 但是、当您尝试解除磁盘故障时、它不会显示为故障
::> disk unfail c07e1.13
Warning: Failed disk "c07e1.13" may have aggregate labels and file system data present. In that case, this command will attempt to bring this disk back into the aggregate with which this
disk had formerly been associated and preserve file system data. Are you sure you want to continue with disk unfail? {y|n}: y
Error: command failed: Failed to unfail the disk. Reason: Disk is not currently failed.