Windows 重新启动后 ONTAP SAN LUN 消失
适用于
- ONTAP 9.14 及更高版本
- SnapMirror
问题描述
- LUN 移动和释放 Snapmirror 一致性组的基础 Snapshot 后 LUN 消失
- 配置 MPIO 时 SCSI 磁盘条目移至隐藏状态
- Microsoft MPIO 在 LUN 迁移后显示
Event ID 47
且所有目标端口的设备名称显示Disk -1
:

- 新
target-port-groups
ID 以更高的顺序创建(即 13e9 位于原始 13e8 之前),并将report_new_rtpgids flag
设置为 1
cluster2::*> debug san lun show-target-port-groups
Vserver Node Path Target Port Groups
------- -------------------- ----- ------------------------------------------
svm1_cluster2 /vol/NetApp/NetApp
<snip>
/vol/vol_sql1_db_dest/sql1_db
cluster2-01 13e9 Active/Non-Optimized: 2
13e8 Active/Optimized: 1
cluster2-02 13e9 Active/Non-Optimized: 2
13e8 Active/Optimized: 1
cluster2::*> statistics show -object lun -counter scsit_lu_flag_status -node cluster2-01 -raw
Object: lun
Instance: /vol/vol_sql1_db_dest/sql1_db
Start-time: 1/8/2025 14:02:33
End-time: 1/8/2025 14:02:33
Scope: svm1_cluster2
Number of Constituents: 1 (complete_aggregation)
Counter Value
-------------------------------- --------------------------------
scsit_lu_flag_status -
lu_readonly 0
report_new_rtpgids 1