Last Updated:

适用场景

  • FlexArray
  • ONTAP 9.x
  • 3PAR阵列 

问题描述

  • 如果使用RAID 0的Flex阵列中缺少一个磁盘、而在第三方存储磁盘上未发现任何问题描述 、则由于多磁盘崩溃、节点已重新启动。
  • 由于磁带驱动器和库分区到同一个存储启动程序端口、因此观察到适配器重置。
Fri Aug 06 11:52:18 +0000 [Node002: slifc_intrd: mlm.tapemc.path.discovery:info]: A new Tape/MC path was discovered: initiator port 1a is now connected to tape library HP_ESLESeries_?'s target port: WWNN: 5001438017cf4654, WWPN: 5001438017cf4655. There are 1 LUNs visible on this target port. Fri Aug 06 11:52:18 +0000 [Node002: slifc_intrd: mlm.tapemc.lun.PathAdded:info]: medium changer LUN 'UYSAN10:81.156L0' (S/N: H6A59A20J5) is now connected on initiator port 1b through HP_ESLESeries_?'s target port: WWNN: 5001438017cf4654, WWPN: 5001438017cf4657 at LUN ID: 0. Fri Aug 06 11:52:18 +0000 [Node002: slifc_intrd: mlm.tapemc.path.discovery:info]: A new Tape/MC path was discovered: initiator port 1b is now connected to tape library HP_ESLESeries_?'s target port: WWNN: 5001438017cf4654, WWPN: 5001438017cf4657. There are 1 LUNs visible on this target port. Fri Aug 06 11:58:38 +0000 [Node002: slifc_intrd: mlm.tapemc.lun.discovery:info]: New medium changer LUN UYSAN10:60.11L0 (S/N: H4A59A20J5) was discovered on initiator port 1b at tape library target port WWNN: 5001438017b7d654, WWPN: 5001438017b7d656. Fri Aug 06 10:41:29 +0000 [Node002: slifc_timeout_0: fci.adapter.error:notice]: Fibre Channel adapter driver encountered error "Device asyncd state stalled" on adapter 1b. Fri Aug 06 10:41:29 +0000 [Node002: slifc_asyncd_0: fci.adapter.reset:debug]: Resetting Fibre Channel adapter 1b

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.