跳转到主内容

由于Brocade交换机重新启动、多个FC目标适配器上的链路中断

Views:
9
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • ONTAP 9
  • Brocade FC 交换机

问题描述

  • 在多个节点的FC适配器上的EMS日志中发现链路中断:
Tue Feb 13 01:11:22 +0000 [node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 1c with event status 1 , topology type 1, status1 0x0, status2 0x0.
Tue Feb 13 01:11:23 +0000 [node2: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 1c with event status 1 , topology type 1, status1 0x0, status2 0x0.
  • SYSCONFIG-A 的节点显示受影响的适配器已连接到同一交换机。例如,两个都连接到 switch2
slot 1: Fibre Channel Target Host Adapter 1c
Switch Port:    switch2:68
 
slot 1: Fibre Channel Target Host Adapter 1c
Switch Port:    switch2:69
  • Brocade交换机 errdump -aKernel Panic 在链路中断时报告重新启动:
2024/02/13-01:32:26, [HAM-1004], 6610602, CHASSIS, INFO, BrocadeG630, Processor rebooted - Software Fault:Kernel Panic.
  • 交换机核心文件 包含 Oops
Oops taken on: 2024-02-13 at 01:31:29:458270
Oops: Machine check, sig: 7 [#1]
  • errdumpall 显示:
2024/02/13-01:32:26:106787, [PLAT-8054], 6628542/0, CHASSIS, INFO, BrocadeG630, Enable PCIe event IRQs 1, syspcie.c, line: 879, comp:rc, ltime:2024/02/13-01:32:22:249888
2024/02/13-01:32:26:106816, [HAM-1004], 6628543/6610602, CHASSIS, INFO, BrocadeG630, Processor rebooted - Software Fault:Kernel Panic., reboot.c, line: 117, comp:hamd, ltime:2024/02/13-01:32:23:265990
2024/02/13-01:32:26:106835, [IPC-5023], 6628544/0, CHASSIS, WARNING, BrocadeG630, HAM_PEER:1745 attempts to send message type(24) to invalid dest(EMIPC:0/0), comm.c, line: 474, comp:hamd, ltime:2024/02/13-01:32:24:280505

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.