适用场景

  • Brocade FC 交换机
  • ONTAP 9

问题描述

  • 同一网络结构中的两个交换机的CRC错误越来越多
  • 交换机1在连接到FC目标适配器的F端口上的crc_errcrc_g_eof 增加:
switchshow     :
[...]
Index Port Address  Media Speed  State    Proto
==================================================
  16  16  011000  id   N16   Online    FC  F-Port  1 N Port + 1 NPIV public 
 
porterrshow     :
      frames     enc   crc   crc  
     tx    rx    in   err   g_eof 
  16:   1.6g   3.1g   0    3.1k  3.0k 
  • 连接到交换机端口的FC目标适配器出现EMS IO错误 :
[BAFF-A-01: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:1c IO WQE failure, Handle 0x1, Type 8, S_ID: 10100, VPI: 259, OX_ID: 2BF, Status 0x3 Ext_Status 0x16
[BAFF-A-01: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:1c IO WQE failure, Handle 0x1, Type 8, S_ID: 11200, VPI: 259, OX_ID: 154, Status 0x3 Ext_Status 0x16
[BAFF-A-01: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:1c IO WQE failure, Handle 0x1, Type 8, S_ID: 10200, VPI: 259, OX_ID: 55F, Status 0x3 Ext_Status 0x16
  • 交换机2在E端口上的crc_err 增加:
switchshow     :
[...]
Index Port Address  Media Speed  State    Proto
==================================================
  23  23  021700  id   16G   Online    FC  E-Port  10:00:88:94:71:12:34:56 "switch1" (downstream)(Trunk master)  
 
porterrshow     :
      frames     enc   crc   crc  
     tx    rx    in   err   g_eof 
  23:   3.2g   3.6g   0    1.1k  0   
  • 所有端口上的SFP发送和接收功率均正常
  •   首先调查增加crc_errcrc_g_eof链路
    • 将缆线移至交换机上的其他端口和SFP后、错误仍会增加
    • 更换电缆后、错误仍会增加
    • 重新拔插连接的设备 SFP后、错误仍会增加

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.