连接到主机端口的 HP 虚拟连接模块关闭 重复
适用于
ONTAP 9
HP 刀片式 VC 模块是主机与 FC 光纤 / 刀片式交换机模块之间的连接。
问题
- 连接到主机端口的虚拟连接模块报告暂停泛洪,并通过禁用主机连接的端口以及丢失存储路径来做出响应。
虚拟连接日志:
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:3102:Major] : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v1:3102:Major] : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v2:3102:Major] : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v3:3102:Major] : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET:enc0:iobay2:3020:Minor] Enet Module state DEGRADED : 1 or more ports LOOP_DETECTED or PAUSE_FLOOD_DETECTED, Previous: Enet Module state OK, Cause: Port enc0:iobay2:d5 pause-flood detected and automatically disabled
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENC:enc0:2014:Minor] Enclosure state DEGRADED : Some Enet modules & servers not OK, Previous: Enclosure state OK, Cause: Port enc0:iobay2:d5 pause-flood detected and automatically disabled
- 此外,主机连接的端口在交换机端充当 " 慢速消耗 " 设备
- 在登录到交换机的某些 NPIV 端口上观察到缓冲区信用超时。
映射交换机端的数据:
Category(Violation Count)|RepeatCount|Rule Name |Execution Time |Object |Triggered Value(Units)|
-----------------------------------------------------------------------------------------------------------------------------
Port Health(6) |5 |ALL_F_PORTS_C3TXT0 |03/04/21 20:26:52|F-Port 11/17 |140 Timeouts |
| | | |F-Port 10/16 |156 Timeouts |
| | | |F-Port 10/16 |120 Timeouts |
| | | |F-Port 3/27 |217 Timeouts |
| | | |F-Port 10/16 |139 Timeouts |