跳转到主内容

在 MetroCluster 切回后 FC 路径降至一个节点

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

适用于

  • ONTAP 9.14.1P9
  • FCP
  • 4 节点 MetroCluster
  • VMware ESXi 7

问题描述

  • 在 MetroCluster 切回后,ESXi 主机到某个节点的 LIF 出现死路径
  • 重新扫描或重启主机无法解决该问题
  • 重新扫描/重启后,这些路径从死路径变为在主机上不再显示
  • 从 ONTAP 进行 FC ping 显示 initiator 无法通过没有路径的 LIF 访问:

::> fcp ping-initiator show -wwpn 51:40:2e:c0:12:34:56:78 -vserver svm_example
  (vserver fcp ping-initiator show)
               Node     Logical   Ping     Extended
Vserver   WWPN        Name     Interface Status    Status
--------- ----------------- ---------- --------- ----------- -----------------
svm_example
[...]
      51:40:2e:c0:12:34:56:78
               node1   lif_fcp01_node1_2c
                         not-reachable
                               -

  • 存储连接交换机可以 ping 通存储和主机:

fabA_switch2:FID128:admin> fcping 20:10:d0:39:ea:12:34:56 51:40:2e:c0:12:34:56:78 
Source:     20:10:d0:39:ea:12:34:56
Destination:   51:40:2e:c0:12:34:56:78
Zone Check:    Zoned

Pinging 20:10:d0:39:ea:12:34:56 [0x650b01] with 12 bytes of data:
received reply from 20:10:d0:39:ea:12:34:56: 12 bytes time:489 usec
received reply from 20:10:d0:39:ea:12:34:56: 12 bytes time:355 usec
received reply from 20:10:d0:39:ea:12:34:56: 12 bytes time:358 usec
received reply from 20:10:d0:39:ea:12:34:56: 12 bytes time:338 usec
received reply from 20:10:d0:39:ea:12:34:56: 12 bytes time:377 usec
5 frames sent, 5 frames received, 0 frames rejected, 0 frames timeout
Round-trip min/avg/max = 338/383/489 usec

Pinging 51:40:2e:c0:12:34:56:78 [0x022a00] with 12 bytes of data:
received reply from 51:40:2e:c0:12:34:56:78: 12 bytes time:761 usec
received reply from 51:40:2e:c0:12:34:56:78: 12 bytes time:696 usec
received reply from 51:40:2e:c0:12:34:56:78: 12 bytes time:744 usec
received reply from 51:40:2e:c0:12:34:56:78: 12 bytes time:764 usec
received reply from 51:40:2e:c0:12:34:56:78: 12 bytes time:755 usec
5 frames sent, 5 frames received, 0 frames rejected, 0 frames timeout
Round-trip min/avg/max = 696/744/764 usec

  • 主机连接的交换机无法 ping 通存储:

fabA_switch1:admin> fcping  20:10:d0:39:ea:12:34:56 51:40:2e:c0:12:34:56:78 
fcping: Error source wwn invalid

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 