跳转到主内容

由于SFP出现故障、FC启动程序端口脱机

Views:
5
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • ONTAP 9
  • Cisco MDS
  • 磁带驱动器

问题描述

  • 通过Cisco交换机连接到磁带存储的FC启动程序端口已脱机,如 SYSCONFIG-A 或中所示 FC-INIT-PORT-INFO.XML
slot 0: FC Host Adapter 0c (QLogic 8324 rev. 2, N-port, <OFFLINE (hard)>)
  • 在EMS中发现链路中断:
Tue Feb 13 22:55:20 +0100 [node1: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 0c.
Tue Feb 13 22:55:50 +0100 [node1: isp2400_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 0c after 30 seconds. Taking the adapter offline.
  • 重新拔插或交换电缆后、适配器将联机几秒钟、然后再次脱机:
Mon Feb 19 09:09:39 +0100 [node1: isp2400_asyncd_0: fci.adapter.online:info]: Fibre Channel adapter 0c is now online.
Mon Feb 19 09:11:46 +0100 [node1: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 0c.
Mon Feb 19 09:12:17 +0100 [node1: isp2400_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 0c after 30 seconds. Taking the adapter offline.
  • 磁带驱动器从节点丢失:

Mon Feb 19 09:12:17 +0100 [node1: isp2400_asyncd_0: mlm.tapemc.lun.removed:notice]: The tape LUN 'XXXXXXXXXXX:XXXXXXXXX' (S/N: XXXXXXXXXX) is no longer visible to this node.

  • 交换机报告TX功率良好、但RX功率低:
`show interface`
[...]
fc1/11 is down (Link failure or not-connected)
[...]
Temperature 32.90 C, Voltage 3.28 V, Current 7.10 mA, TxPower -0.27 dBm, RxPower -40.00 dBm --
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.