适用场景

  • ONTAP 9
  • Cisco
  • FC

问题描述

  • 升级ONTAP后、FC LIF关闭、如下所示。
cluster::> network interface show -status
     Logical       Current     Current  Status
Status
Vserver  Interface      Node       Port   Admin  Oper
-------- ------------------ --------------- --------------- ------
svm-fc
     lif-fc-A-02    node-02     2a    up   down
       Corrective Action: LIF not initialized
  • NPIV在交换机上启用、FCP服务已配置并在ONTAP FC SVM上运行。
  • 升级后端口显示为 link disconnected ,LIF显示为 LIF not initialized
  • 在升级期间、节点重新启动后、端口关闭、重新启动完成后又返回。

Sun Sep 10 02:30:11 +1000 [node-02: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 2a.

  • link break event 在EMS日志中检测到一段时间后端口恢复工作时。

Sun Sep 10 02:30:17 +1000 [node-02: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 2a with event status 1 , topology type 1, status1 0x0, status2 0x0.

  • 端口处于 Link Disconnected 状态、LIF处于 LIF not initialized 状态。

 slot 2: Fibre Channel Target Host Adapter 2a
         (Emulex LPe16000 (LPe16004) rev. 13, <LINK DISCONNECTED>)
         Board Name:     111-xxxxx
         Serial Number:    FP95xxxxxx
         Firmware rev:    12.x.xxx.0
         Host Port Addr:   000000
         FC Nodename:     50:0a:xx:80:xx:xx:xx:9e (500axx8xxxxxxx9e)
         FC Portname:     50:0a:xx:82:xx:xx:xx:9e (500axx8xxxxxxx9e)
         Connection:     No link
         Switch Port:     Unknown

  • 连接到此FC端口的交换机端口在交换机端也已脱机

2023 Sep 10 02:30:14 switch %PORT-5-IF_DOWN_OFFLINE: %$VSAN 2%$ Interface fc1/29 is down (Offline)   
2023 Sep 10 02:30:14 switch %PORT-5-IF_DOWN_LINK_FAILURE: %$VSAN 2%$ Interface fc1/29 is down (Link failure loss of sync)   

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.