适用场景

  • FC
  • VIOS、AIX
  • 光纤池

问题描述

  • CHECK MEDIUM ERROR访问FC LUN时、主机端会收到""。

Check-medium-error.png

  • 最近对网络环境进行了更改。
  • object.store.unavilable EMS日志中会显示以下错误

[?]  Mon Jun 10 08:37:22 -0500 [node-07: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 020xcxc90-xxxx-11ea-95bf-00xcxcxce4602. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:37:12 -0500 [node-08: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 02axcxc3e-xxxx-11ea-bea1-00xcxcx4972. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:36:25 -0500 [node-11: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 3c1xcxc8b-xxxx-11ee-bcd8-d039xcxc18b9. Reason: Inter-cluster LIF not configured.
[?]  Mon Jun 10 08:36:17 -0500 [node-12: OscHighPriThreadPool: object.store.unavailable:EMERGENCY]: Unable to connect to the object store "fabricpool_xyz" from node 61b0xcxcb-xxxx-11ee-882a-d03xcxxc18c9. Reason: Inter-cluster LIF not configured.

  • EMS日志中显示IC正在删除的BIOS错误消息。

[?]  Mon Jun 10 08:37:21 -0500 [node-07: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF node-07_icl07 (on virtual server 42cxcx95), IP address 172.23.xx.yy, is being removed from node node-07, port a0a-1xx1.
[?]  Tue Jun 11 00:48:38 -0500 [node-07: vifmgr: vifmgr.lifsuccessfullymoved:notice]: LIF node-07_icl07 (on virtual server 42xcxcx95), IP address 172.23.xx.yy, is now hosted on node node-07, port a0a-1xx1.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.