跳转到主内容

Brocade交换机端口脱机并处于"无指示灯"状态、Rx电源显示为-INF

Views:
7
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
san<a>2009814150</a>
Last Updated:

适用场景

  • ONTAP 9
  • Brocade

问题描述

  • 交换机端口状态 No_Light switchshow 输出下方显示为:

Index Port Address Media Speed      State   Proto
==================================================
   1  1   XXXXX      id   N4    No_Light    FC

  • portshow 受影响的端口报告 Offline 状态:

portshow 1
portDisableReason: None
portCFlags: XXXX
portFlags: XXXX PRESENT LED
LocalSwcFlags: 0x0
portType:  18.0
POD Port: Port is licensed
portState: 2 Offline
Protocol: FC
portPhys:  4 No_Light  portScn:  2 Offline
port generation number:    XXXX
state transition count:    12

  • sfpshow 将处方状态报告为  -inf

RX Power:    -inf    dBm (0.0 uW)   1.0    uW 6550.0 uW  49.0   uW  1100.0 uW
TX Power:    -6.2    dBm (239.7 uW)  50.0  uW  700.0  uW 100.0  uW   600.0 uW

  • fabriclog 表示端口已转接 Offline

Switch 0; Sun Oct 22 20:28:32 2023 GMT (GMT+0:00)
20:28:32.074305 SCN Port Offline;g=0xa8d2                   D2,P0  D2,P0 1     NA

  • 已更换交换机端的SFP和缆线、但这没有帮助。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.