Brocade交换机端口脱机并处于"无指示灯"状态、Rx电源显示为-INF
适用场景
- ONTAP 9
- Brocade
问题描述
- 交换机端口状态
No_Light
在switchshow
输出下方显示为:
Index Port Address Media Speed State Proto
==================================================
1 1 XXXXX id N4 No_Light FC
portshow
受影响的端口报告Offline
状态:
portshow 1
portDisableReason: None
portCFlags: XXXX
portFlags: XXXX PRESENT LED
LocalSwcFlags: 0x0
portType: 18.0
POD Port: Port is licensed
portState: 2 Offline
Protocol: FC
portPhys: 4 No_Light portScn: 2 Offline
port generation number: XXXX
state transition count: 12
sfpshow
将处方状态报告为-inf
:
RX Power: -inf dBm (0.0 uW) 1.0 uW 6550.0 uW 49.0 uW 1100.0 uW
TX Power: -6.2 dBm (239.7 uW) 50.0 uW 700.0 uW 100.0 uW 600.0 uW
fabriclog
表示端口已转接Offline
Switch 0; Sun Oct 22 20:28:32 2023 GMT (GMT+0:00)
20:28:32.074305 SCN Port Offline;g=0xa8d2 D2,P0 D2,P0 1 NA
- 已更换交换机端的SFP和缆线、但这没有帮助。