跳转到主内容

DNS服务器响应缓慢会导致DNS超时

Views:
41
Visibility:
Public
Votes:
3
Category:
ontap-9
Specialty:
nas
Last Updated:

适用场景

  • ONTAP 9
  • 域名服务(DNS)

问题描述

  • 如果DNS在配置的超时期限内没有响应、则会发生超时
  • EMS会记录以下错误:

[NODENAME: mgwd: dns.server.timed.out:error]: DNS server x.x.x.x did not respond to vserver = svm3 within timeout interval.

或原始EMS文件日志:

<secd_dns_server_timed_out_1
     ipaddr="x.x.x.x"
     vsName="vserver_name"/>

  • SECD.log 中可能会出现错误:

ERR  :  NSLIBC: __res_nsend(), ../../../../../lib/libc/resolv/res_send.c:804, Vsid = 3 Timed out while connecting to DNS server: x.x.x.x via Source Address x.x.x.x. Error: Operation timed out
debug:  Logged secd.dns.server.timed.out to EMS.  { in logEmsEventForDnsError() at src/utils/secd_ems_utils.cpp:1035 }

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.