跳转到主内容

升级ONTAP后、端口2049上会重置许多TCP

Views:
8
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas<a>2009年78404</a>
Last Updated:

适用场景

  • ONTAP 9
  • 9.5之前的NFS实施

问题描述

  • Nblade.nfsConnResetAndClose 在将 ONTAP升级到9.11.1或更高版本后、EMS显示了许多事件
 Nblade.nfsConnResetAndClose: Shutting down connection with the client. Vserver ID is 3; network data protocol is NFS, Rpc Xid 0x0; client IP address:port is 192.168.4.5:57415. local IP address is 192.168.5.5; reason is Idle Timeout, closing connection.
  • NFS服务器选项 allow-idle-connection-timeout 或 allow-idle-connection 将在升级后启用。之前已禁用

cluster::*> nfs show -vserver svm1 -fields allow-idle-connection 
vserver allow-idle-connection-timeout 
------- --------------------- 
 svm1  enabled
  

  • NFSv4.1实施ID显示的是ONTAP 9.5之前的ONTAP版本。   

cluster::> set advanced
 
Warning: These advanced commands are potentially dangerous; use them only when directed to do so by NetApp personnel.
 
Do you want to continue? {y|n}: y
 
cluster::*> nfs show -vserver svm1 -fields v4.1-implementation-name
 
vserver v4.1-implementation-name
 
------- ------------------------
 
svm1  NetApp Release 9.4P3 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.