以太网端口上的 CRC 错误增加
适用于
问题描述
- ONTAP 在事件日志中报告以下消息:
Thu Jul 08 00:17:37 PDT [node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0d on node node1 is reporting a high number of observed hardware errors, possibly CRC errors.
- Ifstat 输出显示片段错误计数器增加。
cluster1::> system node run node1 -command ifstat e0d
RECEIVE
Total frames: 2050k | Frames/second: 5 | Total bytes: 427m
Bytes/second: 1033 | Total errors: 1185 | Errors/minute: 0
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 599k
Non-primary u/c: 0 | Errored frames: 0 | Unsupported Op: 0
CRC errors: 1185 | Runt frames: 0 | Fragment: 0
Long frames: 0 | Jabber: 0 | Length errors: 0
Alignment errors: 0 | No buffer: 0 | Pause: 0
Jumbo: 5 | Error symbol: 0 | Bus overruns: 0
Queue drops: 0 | LRO segments: 1391k | LRO bytes: 367m
LRO6 segments: 0 | LRO6 bytes: 0 | Bad UDP cksum: 0
Bad UDP6 cksum: 0 | Bad TCP cksum: 0 | Bad TCP6 cksum: 0
Mcast v6 solicit: 0 | Lagg errors: 0 | Lacp errors: 0