由于EPIPE错误、Fpolicy连接问题描述
适用场景
- ONTAP 9
- Fpolicy
- Veritas DataInsight
问题描述
按照EMS或、与Fpolicy服务器的ONTAP 连接失败
event log show
9/27/2022 09:37:50 cluster01-02 ERROR fpolicy.server.connectError: Node failed to establish a connection with the FPolicy server "x.y.w.z" of policy "policy1" for Vserver svm1(reason: "Connection to FPolicy server is broken(EPIPE) received."). 9/27/2022 09:37:25 cluster01-01 ERROR fpolicy.server.connectError: Node failed to establish a connection with the FPolicy server "x.y.w.z" of policy "policy1" for Vserver svm1(reason: "Connection to FPolicy server is broken(EPIPE) received."). 9/27/2022 09:36:53 cluster01-01 ERROR fpolicy.server.disconnect: Connection to the FPolicy server "x.y.w.z" of policy "policy1" is broken for Vserver svm1(reason: "FPolicy server is removed from external engine." ). 9/27/2022 09:36:50 cluster01-02 ERROR fpolicy.server.disconnect: Connection to the FPolicy server "x.y.w.z" of policy "policy1" is broken for Vserver svm1(reason: "FPolicy server is removed from external engine." ).