由于卷处于脱机状态、EMS日志报告"Nblade.cifsShrConnectFailed "错误
适用场景
- ONTAP 9
- CIFS
问题描述
- EMS 日志中报告了以下错误信息:
ERROR Nblade.cifsShrConnectFailed: vserverName="SVM1", vserverId="4", errorDescription="Path was incompletely processed other than because of encountering a symbolic link, junction, data set root, or export point", errorCode="257", shareName="NAME", serverIp="x.x.x.x", clientIp="x.x.x.x"
- ONTAP 9.3之前的版本未列出错误问题描述 :
ERROR Nblade.cifsShrConnectFailed: vserverId="4", errorCode="257", shareName="NAME", serverIp="x.x.x.x",
clientIp="x.x.x.x"