跳转到主内容

集群交换机运行状况监控器在 9.8 及更高版本中报告 "SNMP 设置无效 "

Views:
9
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009073495</a>
Specialty:
hw
Last Updated:

适用场景

  • 集群网络交换机
  • ONTAP 9.8

问题描述

  • 在ONTAP 9.8及更高版本中、尝试使用命令"system cluster-switch cree"或"system switch Ethernet cree"创建集群交换机条目失败、并显示以下错误消息:

::> set advanced
::*> system switch ethernet create -device switch1 -address 10.10.10.1 -model OTHER -type cluster-network -is-monitoring-enabled-admin true
Error: SNMP validation request timed out. Verify that the "-community-or-username" value is valid.

  • "system cluster-switch show"命令输出的"reason"字段的值为"Invalid SNMP Settings"
::> system cluster-switch show -type cluster-network
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
switch1 cluster-network 10.10.10.1 N9K-C9336C-FX2
Serial Number: XXXXXXXX
Is Monitored: false
Reason: Invalid SNMP Settings
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
9.3(8)
Version Source: CDP/ISDP
  • ONTAP与交换机之间没有网络连接问题

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.